Isıcam Sinerji 3+ / Konfor 3+
Ug 0.7 · argon 0.6Triple glazing 4+12+4+12+4; 4 times more thermal insulation than ordinary double glazing. Konfor 3+ also adds solar control.
Most of a window’s surface is glass, so your choice of glass directly determines thermal insulation, summer comfort, security and sound. Isıcam Sinerji with its heat-control coating reduces heat loss in winter, Isıcam Konfor adds solar control, and triple glazing delivers the highest insulation. Laminated, acoustic, tempered, tinted and reflective options meet special needs.

Isıcam Sinerji (S series), with its heat-control (Low-E) coating, cuts heat loss by 50% compared with standard Isıcam Klasik® double glazing; it makes maximum use of solar heat without compromising light transmission. It stops the area in front of the window from feeling cold in winter and delays condensation on the glass surface. In standard use the coating is on the inner face of the unit’s outer pane; in regions with very harsh winters it can also be used on the inner pane. This is the basic choice for cold climates where heating dominates.
Isıcam Konfor (K series) halves heating energy and also reduces solar heat gain by 40%, cutting cooling costs in summer as well; it stops the area in front of the window from feeling cold in winter and hot in summer. It is well suited to sun-exposed facades and air-conditioned rooms. It is stated that when Konfor is chosen instead of standard double glazing, the extra cost pays for itself in 1-2 years through savings on air-conditioning investment and on heating and cooling.
For the highest insulation, triple glazing (Sinerji 3+ and Konfor 3+, 4+12+4+12+4) provides 4 times more thermal insulation than ordinary double glazing; the Ug value is 0.7 W/m²K with air and 0.6 W/m²K with argon, giving heat control equivalent to an uninsulated brick wall. Its low reflection improves comfort in projects where the view matters. Filling the cavity with 90% argon instead of air can improve the insulation value by up to 16%, and with krypton by up to 27%. Argon is neither flammable nor explosive and does not react with any substance; with an annual leakage rate of 1%, it maintains its performance for about 20 years.
For special needs: laminated insulating glass holds its fragments in place when broken, prevents or delays entry in attacks with stones or sticks, and blocks 97-99% of UV rays, reducing fading of furniture and fabrics. Acoustic laminated insulating glass adds noise reduction to the safety properties of laminated glass, bringing outside noise down to the level of a quiet room. Tempered insulating glass breaks into small, blunt pieces; tempered heat-control glass is about 5 times stronger than untempered glass. Tinted (green, blue, turquoise, bronze, grey, dark grey) and reflective glass limit solar heat gain and glare; reflective glass gives one-way vision from inside to outside during the day.
| Measurement standards | Daylight and solar energy EN 410 · U value EN 673 |
|---|---|
| Ordinary double glazing 4+12+4 | Ug 2.9 air · 2.7 argon · light transmission 80% |
| Ordinary double glazing 4+16+4 | Ug 2.7 air · 2.6 argon · light transmission 80% |
| Isıcam Sinerji 4+12+4 | Ug 1.6 air · 1.3 argon · light 79% · total solar energy transmittance 56% |
| Isıcam Sinerji 4+16+4 | Ug 1.3 air · 1.1 argon |
| Isıcam Konfor 4+16+4 | Ug 1.3 air · 1.1 argon · light 71% · total solar energy transmittance 44% |
| Isıcam Sinerji 3+ 4+12+4+12+4 | Ug 0.7 air · 0.6 argon · light 69% · total solar energy transmittance 39% |
| Isıcam Konfor 3+ 4+12+4+12+4 | Ug 0.7 air · 0.6 argon · light 63% · total solar energy transmittance 39% |
| Argon / krypton filling | Insulation value up to 16% better with 90% argon, up to 27% with krypton |
| Gas retention | With an annual leakage rate of 1%, performance is maintained for about 20 years |
| Laminated glass | Blocks 97-99% of UV; holds fragments in place when broken |
| Tempered glass | About 5 times stronger than untempered glass; breaks into small, blunt pieces |
Values are centre-of-glass thermal transmittance (Ug, W/m²K, EN 673); a lower value means better insulation. The first value is for an air-filled unit, the second for an argon-filled unit.

Triple glazing 4+12+4+12+4; 4 times more thermal insulation than ordinary double glazing. Konfor 3+ also adds solar control.

4+16+4 double glazing with heat-control coating; 50% less heat loss than Isıcam Klasik.

4+16+4 heat and solar control; reduces solar heat gain by 40%.

4+16+4 standard double glazing; the starting point for comparison.
Laminated, acoustic laminated, tempered, tinted (green, blue, turquoise, bronze, grey, dark grey) and reflective (Tentesol, Tentesol Titanyum) glass can be combined with Isıcam Sinerji and Isıcam Konfor.
Both have a heat-control (Low-E) coating and a Ug value of 1.3 (1.1 with argon) in a 4+16+4 unit. Sinerji makes maximum use of solar heat; Konfor reduces solar heat gain by 40%, also lowering cooling costs in the summer months.
In regions where heating dominates, Isıcam Sinerji is the basic choice; in areas with very harsh winters the coating can also be used on the inner pane. For the highest insulation, triple Sinerji 3+ with argon goes down to Ug 0.6.
On sun-exposed facades and in air-conditioned rooms, Isıcam Konfor reduces solar heat gain by 40%. Tinted and reflective glass also limit solar heat gain and glare.
Filling the cavity with 90% argon instead of air improves the glass’s insulation value by up to 16%. Argon is neither flammable nor explosive and does not react with any substance; with an annual leakage rate of 1%, it maintains its performance for about 20 years.
The price depends on the window size, profile series, opening type, glass type and colour. You can see how the calculation works on our price calculator page (https://aga.com.tr/pvc-pencere-fiyatlari-ve-fiyat-hesaplama/) and send your measurements to our WhatsApp line (+90 444 2 333) for a quote.
Send us your window sizes and glass preference and we will prepare a tailored quote: +90 444 2 333